Set-up Part Sets
TheTS590canbeconfiguredtohaveuptothreepartssetmodes(PartSetA,PartSetBand
PartSetC).Thisoptionallowsthemasterusertoconfigureeachpartsetmode.Withineach
part set mode you must designate which circuits will remain armed and which circuits will
be omitted. When the relevant part set modeis selectedthe system only arms the circuits
that are designated as armed and isolates the circuits that are designated as omitted.
1. From the unset (open) mode enter your passcode and press [ENT] twice to select
user menu 2.
2. Whilstuser menu2 is selected. Press [8] to
select the set-up part sets option.
3. Select the part set mode you require to
set-up by pressing [A], [B] or [C] then
[ENT].
4. Select the required circuit by either
entering the circuit number or by using
the [A] and [C] keys to scroll up and
down through the circuits.
5. When the required circuit is displayed,
press [B] to alternate between “Armed”
and “Omitted”. An armed circuit will
remain armed when the system part set,
an omitted circuit will be isolated when
the system is part set.
6. When the display shows the required
setting press [ENT] to accept. A rising
multi-tone will be heard and the next
available circuit is displayed.
7. Repeat from step 3 for other circuits or
press [ESC] three times to return to the
open mode.
29
User menu 2
Select Option :-
Sales Office
CCT 05 Omitted
Canteen Door
CCT 06 Armed
SYSTEM OPEN
17:30 01 JAN
Configure Omits
for part set A
Accounts Office
CCT 01 Armed
SYSTEM OPEN
17:31 01 JAN
ENT
8
B
1
2
3
4
5
7
LCD Remote
? ? ? ?
ENT
+
ENT
A
or
B
or
C
ENT
A C
/
Sales Office
CCT 05 Armed
ESC ESC ESC
6