Detector Circuit Connections
The right hand edge of the main PCB provides a connector for the six zones
and the Entry/Exit Zone, see Figure 12. Each zone (circuit) should have an
Anti-Tamper circuit associated with it. Link all the zone anti-tamper circuits in
series and then connect them to the A/T terminals on the main PCB.
STR
BELL
12V
0V
TR
+
LS
O/P
DATA
CLK
Z1
Z5
Z2
Z3
Z4
Z6
E E
A/T
+ -
12V AUX
Alarm contact for Zone 6
Alarm contact for Zone 4
Alarm contact for Zone 2
Anti Tamper contacts for
Note: If you do not wish to use the global anti-tamper,
connect the A/T terminals together with a short piece
of wire.
zones 2, 4 and 6, in series
Figure 12. Detector Circuit Connections
Connecting Door Contacts
Figure 13 shows the connections for one door contact per zone loop. Use
four core cable for the tamper and circuit connections. Note that the reed
switch inside the door contact is connected to the plated screws (shown in
black in Figures 8 and 9).
Z6
E E
A/T
+ -
12V AUX
To anti tamper loop
for remaining zones
Z6
E E
A/T
+ -
12V AUX
Surface Contact Flush Contact
To anti tamper loop
for remaining zones
Figure 13. Connecting One Door Contact per Zone
3. Installation