Cooper 9448ES Wartungshandbuch Seite 26

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 60
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 25
26 496574
UK
The panel beeps twice to show that it has accepted the command. All
the LEDs flash, and the panel is ready for the next command.
The panel gives a single error tone if you enter an incorrect command.
Re-enter the correct command.
3. Key in "99 R" to leave programming mode when you have finished.
You will then be in user mode.
Engineer Program Command List
To change: Key-in: followed by: Notes
Zones omitted in 10 R zone n..n R LEDs ON for zones
Part Set* omitted (see note 1)
Chime 11 R zone n..n R LEDs ON for chime
(EE zone = zone 7)
Zones Not Used 15 R zone n..n R LEDs OFF for zone
not used (see note 2)
Engineer Code 20 R new code R 4 digits
User Code 1 21 R new code R 4 digits (see note 3)
User Code 2 22 R new code R 4 digits (see notes 3 & 4)
Silent Part set 35 R 0 R Audible
1 R Silent
Zone 2 Entry 36 R 0 R Normal Alarm
Route 1 R Entry Route
Auto Re-Arm 40 R 1 R Never rearm
2 R Rearm once
3 R Rearm twice
4 R Rearm three times
5 R Rearm always
Bell Time 42 R 1 R 90 seconds
2 R 3 minutes
3 R 10 minutes
4 R 20 minutes
Entry time 43 R 1 R 10 seconds
2 R 20 seconds
3 R 30 seconds
4 R 45 seconds
5 R 1 minute
Exit time 44 R 1 R 10 seconds
2 R 20 seconds
3 R 30 seconds
4 R 45 seconds
5 R 1 minute
4. Programming