Seitenansicht 49
DF6000 - USER MANUAL
50
Panel Controls and Indicators
1. System LED’s
2. Zonal LED’s
3. Touch Screen Display
4. Printer Access Door
5. Slot for Optional Printer
Section 4 - Panel Controls and Indicators
Powe r
ON
Powe r
ON
FIRE
FIRE
General
FAUL T
General
FAUL T
System
DISABL E
System
DISABL E
System
FAUL T
System
FAUL T
System
TEST
System
TEST
Charge
FAUL T
Charge
FAUL T
Battery
FAUL T
Battery
FAUL T
1
2
3
4
5
6 7
8
9
21
21
22
22
23
23
24
24
10
10
11
11
12
12
13
13
14
14
15
15
16
16
17
17
18
18
19
19
20
20
25
25
26
26
27
27
28
28
29
29
30
30
31
31
32
32
33
33
34
34
35
35
36
36
37
37
38
38
39
39
40
40
41
41
42
42
43
43
44
44
45
45
46
46
47
47
48
48
49
49
50
50
51
51
52
52
53
53
54
54
55
55
56
56
57
57
58
58
59
59
60
60
61
61
62
62
63
63
64
64
65
65
66
66
67
67
68
68
69
69
70
70
71
71
72
72
73
73
74
74
75
75
76
76
77
77
78
78
79
79
80
80
81
81
82
82
83
83
84
84
85
85
86
86
87
87
88
88
89
89
90
90
91
91
92
92
93
93
94
94
95
95
96
96
Zones
Zones
1
2
3
4
5
12 3 45 6 78 9 10 11
Power
ON
Power
ON
FIRE
FIRE
General
FAUL T
General
FAUL T
Extinguisher
ACTIV ATED
Extinguisher
ACTIV ATED
System
DISABLE
System
DISABLE
System
FAUL T
System
FAUL T
System
TEST
System
TEST
Power
FAUL T
Power
FAUL T
Zones
Disabl e
Disabl e
Faul t
Faul t
Disable
Disable
Faul t
Faul t
Sounder
Sounder
FRE
FRE
Delay
ACTIVE
Delay
ACTIVE
LED Name Function Action
1 Power On Shows Panel is On Check Indicator is Illuminated
2 Fire Indicators Panel has Detected a Fire Impliment Fire Action Procedure
3 General Fault Monitors Devices for Faults e.g. Smoke detectors/Sounders Report to System Supervisor
4 System Fault Monitors Fire Panel for Faults Report Fault to Service Dept
5 Power Fault Monitor Internal Battery Charger Report Fault to Service Dept
6 Sounder Monitors Sounder Circuits/Indicates Disablement of this Output Report Fault to Service Dept
7 System Disable Part of the System has been Disabled Report to System Supervisor
8 System Test Supervisor/Engineer is Testing the System Check with System Supervisor
9 FRE Monitors the FRE Circuit/Indicates Disablement of this Output Report Fault to Service Dept
10 Extinguisher Activated Display Activatiion of Extinguishers (If Option Fitted) Check with System Supervisor
11 Delay Active Delays on Outputs Active Check with System Supervisor