1-6 SPARC Enterprise Mx000 Servers XSCF User’s Guide • December 2010
administrators or FEs to configure the system settings, display the system status, and perform
component replacement tasks. For details on using the LAN ports, see Section 1.3, “Types of
Connection to XSCF” on page 1-14 and Chapter 3.
Link Speed LED
Located on each of the XSCF-LAN ports, the Link Speed LED is a LAN LED that lights up
in green. The Link Speed LED is turned on when a 100-Mbps LAN connection is
established, and it is not turned on when a 10-Mbps LAN connection is established.
ACT LED
Located on each of the XSCF-LAN ports, the ACT LED is a LAN LED that lights up in
green. When the communication state is Link up, the ACT LED lights up. When the
communication state is Link down, the ACT LED light is off. The ACT LED light is off
while data is being sent/received though the associated LAN connection. So, the ACT LED
looks as if it is blinking.
UPC Port
There are two UPC ports. These ports are a connection between the XSCF Unit and the UPS.
The UPC port is used only when a UPS is connected. For details on the connectors, see the
Service Manual for your server.
XSCF Unit Panel (Front) on the Midrange Servers
FIGURE 1-2 is an outline drawing of the XSCF Unit front panel on the M4000/M5000 servers.
The XSCF Unit of the M4000/M5000 servers is a removable unit. In the M4000/M5000
servers, for details on mounting the XSCF Unit, see the SPARC Enterprise M4000/M5000
Servers Service Manual.