Appendix D Troubleshooting D-5
Alert Message is Displayed in XSCF Web
Please confirm the content of the security alert message and stop the use of XSCF Web.
Perform the countermeasure to the content of the confirmed warning. When the expiration
is over, re-set the https setting of XSCF. For the details of settings, see Section 2.2.8,
“Https Administration” on page 2-109 in Chapter 2.
Other Problems
Contact the system administrator. If XSCF log data must be collected, use the XSCF Shell
command to collect it. For information about the log collection method, see Section 8.2,
“Collecting XSCF Logs” on page 8-22.
Frequently Asked Questions (FAQ)
Q. Is an IP address assigned by default to the LAN port used for the XSCF-LAN?
A. An IP address is not assigned by default. If an IP address were assigned by default, one IP
address would be temporarily duplicated during the concurrent setup of multiple units. This
may affect the user LAN environment. To prevent this, the XSCF-LAN network function is
disabled by default. However, there is a default value for the IP address for the network
connecting redundantly configured XSCF Units (ISN). For information about the default
value, see Section 2.2.1, “Network Configuration” on page 2-16 in Chapter 2.
Q. If an Oracle Solaris OS hang-up event occurs during Oracle Solaris OS startup after the
main unit is powered on, can the main unit power be turned off?
A. If an Oracle Solaris OS hang-up event occurs, the first action is to do the following
instead of turning off the main unit power:
1. First, execute the reset(8) command with the panic option from the XSCF Shell.
2. After doing Step 1, if the Oracle Solaris OS dump fails, move to the ok prompt by
executing "Break", or executing the reset(8) command with the xir option from the
XSCF Shell. At this point, execute the "sync" command.
3. After doing Step 2, if the reset operation or the "sync" command fails, execute the
reset(8) command with the "por" option from the XSCF Shell, or forcibly turn off
power by using any of the following methods:
Method 1. Press and hold down the POWER switch on the operator panel of the main unit
for four seconds.
Method 2. Execute the poweroff(8) command from the XSCF Shell.
Q. What kind of processing is executed by XSCF from the time that input power to the main
unit is turned on until the Oracle Solaris OS starts?