Quick Reference Engineers Menus
Engineers Menu 1
key Options Page
1
Program Panel Outputs
1 = Panel Output 1 (relay)
2 = Panel Output 2 (-ve)
3 = Panel Output 3 (+ve)
26
2
Program Digicom Outputs
1 = Channel 1
2 = Channel 2
3 = Channel 3
4 = Channel 4
5 = Channel 5
26
3
Program Digicom Channels
1 = Channel 1 5 = Channel 5
2 = Channel 2 6 = Channel 6
3 = Channel 3 7 = Channel 7
4 = Channel 4 8 = Channel 8
26
4
Program Circuits & Attributes
Circuit Types Circuit Attributes
0 = Not Used 1 = Access
1 = Night 2 = D Knock
2 = 24 Hour 3 = Test
3 = PA Silent 4 = Omit
4 = PA Audible 5 = Reset
5 = Fire 6 = Monitored
6 = Auxiliary 7 = Entry
7 = Final Exit 8 = Chime
8 = Exit Term. Lock Switch Attributes
9 = Keyswitch F,A,B,C = wards
L = Lockset
M = Momentary
I = Inverted
29
5
System Timers
00 = Abort Delay 12 = Monitor Dur.
01 = No Rearms 13 = Pset Bell Dly
02 = Settle Time 14 = Courtesy Dur.
03 = Pset Com Dly 15 = No Rem. Resets
04 = Exit time 16 = Modem Rings
05 = Entry Time 17 = CID Alarms
06 = Bell Dur. 18 = AC Off Delay
07 = Bell Dly 19 = Test Call
08 = Double Knock 20 = Confirmation
09 = Test Time 21 = Line Fault Dly
10 = 2nd Entry 22 = Service Time
11 = Part Set Entry 23 = Test Call At
31
6
Setting Modes
0 = Full Set 1 = Final Exit
A = Part Set A 2 = Exit Terminator
B = Part Set B 3 = Timed Exit
C = Part Set C 4 = Instant
5 = Deferred
6 = Lock set
33
7
System Print-Out
33
8
Remote Reset Algorithm
Enter Algorithm number 004 - 199.
34
key Options Page
9
System Configuration
No. Yes No
00 = Bell is an SAB Bell is an SCB
01 = User 1 Limited User 1 Unlimited
02 = Fire Signals All Fire Signals Set
03 = Silent 24hr Ccts Audible 24hr Ccts
04 = Enable Duress Disable Duress
05 = Invert Abort O/P Normal Abort O/P
06 = Set with LF Can’t Set with LF
07 = User Reset Engineer Reset
08 = Extended Format Fast Format
09 = Hi-Sec Engineer Lo-Sec Engineer
10 = Tamp User Reset Tamp Engr Reset
11 = Do Battery Test No Battery Test
12 = F.Exit Is Night F.Exit is Normal
13 = User Code + ENT User Code Only
14 = Show P.Set Info Show Time Only
15 = Dial Consecutively Dial Alternatively
16 = Set with AC Off No Set with AC Off
17 = Loud Chime Normal Chime
18 = Invert O/P 1 Normal O/P 1
19 = Invert Digi O/Ps Normal Digi O/Ps
20 = Online Keypad No Online Keypad
21 = Restore PID PID Alarms Only
22 = User Authorised No Authorisation
23 = Mimic Alm & Flt Mimic Alarm Only
24 = Monitor Off Hook Monitor Line Cut Only
25 = Answerphone Def. Normal Answer
26 = Send Open/Close No Open/Close
27 = Tampers always Tampers when set
28 = 24hr ccts always 24hr ccts when set
29 = Keypad PA Silent Keypad PA Audible
30 = Snders on Confirm Sndrs on First Alarm
31 = Bells on Confirm Bells on First Alarm
32 = Conf after Entry No Conf After Entry
33 = Confirmation On Confirmation Off
34 = Entry kpd locked Entry kpd free
35 = TA as Burg TA as TA
36 = Ent. conf after 2cct After 1 cct
37 = Unconf Usr Rst Unconf Eng Rst
38 = Keypad PA On Keypad PA Off
34
0
Go To User Menu 1
36
A
Add/Clear ID Devices
A = Add ID Devices
B = Toggle ID Status and View Circuits Mode
C = Clear and Learn all ID Devices
0 = Toggle SLOW SCAN Mode and Normal
37
B
View Location Text
37
C
Re-Map ID Devices & Relearn Hardware
Re-Map ID Devices (TS690ID Only)
1. Enter Device No 01 - 30 then ENT.
2. Enter Circuit No 01 - 38 then ENT.
3. Repeat for other devices.
Relearn Hardware
Clears the “RELEARN REQUIRED” / ”RESET
CONFIG” message and logs all devices on to
system.
38