Quick Reference User Menus
User Menu 1
key Options
1
Bell Test
2
Walk Test
3
Remote Reset
Enter Reply code + ENT
4
Change Passcode (user)
Enter new passcode
5
Enable Chime
1 = Disabled
2 = Enabled
3 = Enabled in P/Set
4 = Enabled in Unset
6
Omit Shunt Group
7
Omit Circuits
A = Scroll Next Circuit
B = Toggle Armed / Omitted
C = Scroll Previous Circuit
8
Silent Set
0 = Silent Full Set
A = Silent Part Set A
B = Silent Part Set B
C = Silent Part Set C
0
Full Set
A
Part Set A
B
Part Set B
C
Part Set C
User Menu 2
key Options
1
View Circuits
A = Scroll Next Circuit
C = Scroll Previous Circuit
2
Set System Time
Enter time e.g. 1400 for 2.00pm
3
Set System Date
Enter date e.g. 2804 for 28 April
4
Setup New Users
1. Enter user Number 01 - 15.
2. Select user type:-
1 =Master
2 = Standard
3 = Holiday
4 = Set Only
5 = Reset Only
6 = Duress
7 = PA Code
8 = Shunt
3. Enter 4 digit passcode.
4. Repeat for other users.
5
Chime Circuits
A = Scroll Next Circuit
B = Toggle Chime / Silent
C = Scroll Previous Circuit
6
Alter Shunt Group
A = Scroll Next Circuit
B = Toggle Armed / Omitted
C = Scroll Previous Circuit
7
Print System Log
Enter Number of events and press ENT
8
Configure Part Sets
A = Scroll Next Circuit
B = Toggle Armed / Omitted
C = Scroll Previous Circuit
9
View System Log
A = Scroll Backwards
B = Toggle Name / Circuit Text
C = Scroll Forwards
0
Enable Remote Service
B = Toggle enabled / Disabled
A
Start Call Back
1 = Call Back No. 1
2 = Call Back No. 2
3 = Call Back No. 3
ENT to start Call Back
B
Circuit Text
57
TS690 & TS690ID Installation Manual Appendices